Every service visit
What a generator maintenance visit covers
A standby generator can sit for months and then has to start and carry load in seconds. Scheduled service is how you find the dead battery, the cracked hose and the failed block heater on a quiet Tuesday instead of during an outage.
Each visit ends with an inspection report: what we checked, what we found, the run hours and anything that needs attention before the next visit.
- Full inspection and written reportEngine, alternator, controls, enclosure, fuel system and transfer switch.
- Oil, filters and oil samplingEngine oil and filter, fuel and air filters, with oil samples for analysis where it's called for.
- Cooling systemCoolant level and condition, radiator, hoses, belts, thermostats and block heater.
- Batteries and chargerBattery test and replacement on schedule, charger output and connections.
- FuelFuel level, leaks and lines, and diesel top-off when you want us to handle it.
- Transfer switch and exerciserCheck the automatic transfer switch and confirm the exerciser is running the unit.
- Run testStart, run and check voltage, frequency, oil pressure and temperature, with load bank testing when needed.
Maintenance agreements
One agreement for every unit you run
Most of our long-time customers are on a preventive maintenance agreement. Many run several units, sometimes across several sites, and have trusted us with them for years. We set the visit schedule with you, from the manufacturer's service intervals, the unit's run hours and any code requirements that apply to your site.
Agreement customers already have their units in our records, so when something does go wrong our technicians know the equipment before they arrive. See generator repair.
Equipment we know
Generator brands we service
We service generators we didn't sell, diesel and gas, from 7 kW to 1,000 kW.
Brand names are trademarks of their owners and are listed to show the equipment we work on.
- Generators
- Generac, Kohler, Cummins Onan, Baldor, Katolight, Olympian, Winco
- Engines
- Ford, Kubota, PSI, Volvo Penta, Isuzu, John Deere, Detroit Diesel
- Transfer switches
- ASCO, Generac
- Fuel
- Diesel, natural gas and LP
Questions
Frequently asked questions
How often should an industrial generator be serviced?
Follow the manufacturer's service intervals, which are set by run hours and by time, and most standby units call for at least an annual service. Emergency power systems covered by NFPA 110 also need weekly inspections and a monthly exercise run, which your staff or ours can handle. We set the schedule with you.
What is included in a generator maintenance agreement?
Scheduled visits with a full inspection, oil and filter service, cooling system, belts and hoses, battery and charger checks, fuel system checks, a transfer switch check and a run test, with a written report after each visit. Load bank testing can be added where your site needs it.
Do you service generators at more than one site?
Yes. Many of our customers run several units across several sites, and we keep each unit's history in our records.
Can you bring a neglected generator back into service?
Yes. We do full cleanings and service on units that have sat for years, including one recent site where the generators had been taken over by weeds and mice.
Do you service generators you didn't sell?
Yes. Our service records cover Generac, Kohler, Cummins Onan, Baldor, Katolight, Olympian and Winco generators, among others.
Do you service home standby generators?
Yes. Industrial and commercial units are our focus, but we still service and maintain home standby generators, including air-cooled Generac and Kohler units, for homeowners across Indiana.
Related services
More from Indiana Power
Serving all of Indiana from Tipton for over 38 years. See the cities we serve.